Voltage class · HV
110 kV / 132 kV cable insulation & semiconductive compounds
For 110 kV and its neighbours, 115, 132 and 138 kV, the Borlink™ grades are LE4244S or LS4201S insulation and the LE0592S screen; the cable maker selects and qualifies the pair. All four voltages sit inside the stated application of these Borlink™ HV grades, and IEC 60840 is the cable test standard. Check your Um, whether the design needs prequalification, and your insulation wall against your line, then send us your cable design, grade and volume. We supply all three grades; core grades are held in our Shanghai warehouse.
Grades for 110 kV cables
| Layer | Grade | Notes |
|---|---|---|
| XLPE insulation | Borlink™ LE4244S | Very low sagging — horizontal lines and thick CCV walls |
| XLPE insulation | Borlink™ LS4201S | Excellent scorch resistance; reduced degassing burden |
| Conductor & bonded insulation screen | Borlink™ LE0592S | Very smooth screen; also the conductor screen in strippable constructions |
Choosing between the insulation grades: LE4244S has very low sagging properties and is specially designed for extrusion on horizontal lines and for thick insulation walls on CCV lines. LS4201S is based on Supercure technology, and its sheet separately lists very good electrical performance, excellent scorch resistance for long production runs and high productivity from a reduced degassing burden. Horizontal lines or thick CCV walls point to LE4244S; long runs or a lighter degassing burden point to LS4201S. Compare them in LE4244S vs LS4201S.
All four insulation sheets state superclean insulation, assured through the Borealis Quality Management system. More on XLPE insulation and semiconductive screens.
110 kV at a glance
| Rated voltage U (phase to phase) | 110 kV (115 kV in the other IEC 60038 series) |
|---|---|
| Highest system voltage Um | 123 kV (IEC 60038 Table 4) |
| Cable test standard | IEC 60840: above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV) |
| Constructions covered | Single-core and individually screened three-core cables; not submarine cables |
| Borlink™ band | HV AC: rated up to 230 kV (Um = 245 kV) |
| Grades we supply | LE4244S, LS4201S, LE0592S |
Which standard applies
IEC 60840 applies to this class. It allows type approval of a complete cable system, of cables alone or of accessories alone, and adds a prequalification (PQ) test of the cable system for highly stressed designs. IEC 60840:2020 is Edition 5.0; the consolidated Edition 5.1 (2023) adds Amendment 1:2023 and its 2025 corrigendum.
Standards listed under “Specifications” on each data sheet:
| Grade | Standards listed |
|---|---|
| LE4244S | IEC 60840, IEC 62067, AEIC CS9, ANSI/ICEA S-108-720, HD 632 S1 |
| LS4201S | IEC 60840, IEC 62067, AEIC CS9, ANSI/ICEA S-108-720, HD 632 S1 |
| LE0592S | IEC 62067, AEIC CS9, ANSI/ICEA S-108-720; IEC 60840 not listed |
The LS4201S and LE0592S sheets say the grade “is expected to meet the applicable requirements” of the listed standards, provided it is processed using sound material handling and processing practices and appropriate testing procedures; the LE4244S sheet lists its standards without that sentence. The HV sheets apply these listings only up to their stated limit of 230 kV (Um = 245 kV), although some standards may cover wider voltage ranges. See also our quality & standards page.
What to check
System voltage and Um
| Nominal voltage | Um | Basis |
|---|---|---|
| 110 kV | 123 kV | IEC 60038; VDE FNN for Central Europe |
| 115 kV | 123 kV | IEC 60038; PJM operating range 109–121 kV |
| 132 kV | 145 kV | IEC 60038; National Grid TS1 |
| 138 kV | 145 kV | IEC 60038; PJM operating range 131–145 kV |
| 150 kV | 170 kV | Non-preferred in IEC 60038; top of IEC 60840 |
| 110 kV (China) | 126 kV | GB/T 11017.2-2024 title |
Systems in this class include Germany’s 110 kV network, North American subtransmission at 115 or 138 kV, and 110 or 132 kV connections for 50–150 MW projects in Queensland (Powerlink).
In IEC 60038, 110 kV pairs with 123 kV and 132 kV with 145 kV, and a country should use only one of the two, so a 132 kV cable is a different Um class from a 110 kV cable. Every row still sits inside IEC 60840 and inside the HV sheets’ stated application, up to 230 kV (Um = 245 kV).
Design and testing
- Prequalification. Calculate your stresses first. Under Amendment 1, PQ is required where the calculated nominal stress exceeds 8.0 kV/mm at the conductor screen and/or 4.0 kV/mm at the insulation screen, unless, for example, the same construction with accessories of the same family is already prequalified at an equal or higher rated voltage. For 66–132 kV XLPE cables, the UK’s BS 7912:2012+A1:2017 refers to the IEC 60840:2011 PQ test above the same stresses and notes that its cable systems do not normally have such high stresses.
- Insulation wall. ABB’s land cable guide (rev. 5, 2010) lists single-core 110 kV cables with 16.0 mm of insulation at 185 mm² and 13.0 mm from 400 to 2500 mm², and 132 kV cables with 18.0 and 15.0 mm at the same sizes. These are indicative, non-binding data, so size the wall from your own design.
- Your line. The wall has to fit your line’s range. Maillefer, for example, specifies its EPL 50 Enter catenary (CCV) line for 10–110 kV cables with 3.4–21 mm of insulation.
- Screen listing. IEC 60840 appears on the two insulation sheets, not on LE0592S. If your specification needs it on the screen as well, raise it when you inquire.
- Your own testing. Each sheet describes its grade used alone and leaves suitability testing to the customer.
How to inquire
Core grades are held in our Shanghai warehouse in original sealed packaging, with batch traceability and COA on request: short lead times, no waiting for a production run. We confirm availability of a given grade when you inquire. What each data sheet says on shelf life and storage is in our storage guide.
Tell us your cable design, grade and volume, and we reply with availability, data sheets and pricing. Request a quote →
Installed 132–150 kV XLPE cables
- Radsted–Rødby, Denmark: 132 kV, 25 km, 630 mm² Al, XLPE, 1999.
- Radsted–Vantore Str., Denmark: 132 kV, 18 km, 1200 mm² Al, XLPE, 2002.
- Koksijde–Slijkens, Belgium: 150 kV, 30 km, 2000 mm² Al, XLPE, 2006.
- Tihange–Avernas, Belgium: 150 kV, 30 km, 2000 mm² Al, XLPE, double circuit, 2003.
Shown to illustrate the voltage class, not projects supplied by Lexin.
Further reading
- How IEC 60840 differs from IEC 62067
- Borlink™ LE4244S vs LS4201S compared
- Conductor screen vs insulation screen
- Shelf life and pre-drying of HV compounds
- What Um means
Building an HVDC link? Borlink™ LE0550DC is a semiconductive compound for XLPE HVDC cable screens; its data sheet lists IEC 62895 and CIGRE TB 852 and states no voltage rating.
References
- DATA SHEETS · LE4244S Ed.4 · 2026-03, LS4201S Ed.6 · 2026-05, LE0592S Ed.5 · 2026-03 · Borealis
- STANDARD · IEC 60840:2020 · scope
- STANDARD · IEC 60840 Ed.5.1 preview · introduction
- STANDARD · IEC 60840 AMD1:2023 preview · clause 13.1
- STANDARD · BS 7912 (BSI)
- STANDARD · IEC 60038 Ed.7.1 · Table 4
- STANDARD · PJM design criteria
- STANDARD · National Grid TS1
- STANDARD · GB/T 11017.2-2024
- STUDY · VDE FNN (2019)
- GRID · Bundesnetzagentur network levels
- GRID · Powerlink connection sheet
- WIKI · Electric power transmission
- REPORT · CIGRE WG B1.07 · Table G2
- GUIDE · ABB XLPE Land Cable Systems User’s Guide, 2GM 5007 GB rev. 5 (2010) · Tables 25–26
- EQUIPMENT · Maillefer catenary lines
Other voltage classes
220 kV · 330 kV · 500 kV · All products