Technical insights
Selection guides and background on high-voltage cable materials — written for the engineers and buyers who specify them.
- What is XLPE? Cross-linked polyethylene in power cables XLPE explained: how cross-linked polyethylene differs from PE, why XLPE cables are rated 90 °C, peroxide vs silane vs electron-beam crosslinking, density and melting point.
- LE0592S vs LE0500: Borlink™ semicon screens compared Borlink™ LE0592S (HV) and LE0500 (EHV) semiconductive screen compounds side by side from the 2026 data sheets: application, screen roles, properties, drying.
- Borlink™ LE4244S vs LS4201S: XLPE grades compared Low-sag LE4244 or Supercure-based LS4201? The four Borlink™ HV and EHV XLPE insulation grades compared from the 2026 data sheets, incl. shelf life.
- How to read a Borlink™ data sheet A section-by-section guide to the 2026 Borlink™ product data sheets: application and Um, standards, test methods, footnotes, processing, storage, disclaimer.
- HV cable materials glossary: XLPE, CCV, Um and more Sourced definitions of terms on HV cable compound data sheets and specs: superclean, Supercure, scorch, sagging, degassing, CCV, triple extrusion, Um, PQ.
- IEC 60840 vs IEC 62067 for HV cables: scope, Um, PQ test IEC 60840 covers extruded cable systems above 30 kV up to 150 kV; IEC 62067 above 150 kV up to 500 kV. Scope, Um, PQ tests and what Borlink™ sheets list.
- Foam extrusion with Teflon™ FFR 770 Teflon™ FFR 770 foam extrusion from the Chemours data sheet: typical cable core, void control, contact metals, licensing, safety and typical properties.
- XLPE compound shelf life, storage and pre-drying Shelf life, storage temperature, conditioning, FIFO and drying for Borlink™ XLPE insulation and semiconductive compounds, grade by grade from the 2026 sheets.
- Choosing XLPE insulation for 500 kV EHV cables LE4244EHV or LS4201EHV for 330–500 kV cables? What each Borlink™ data sheet stresses, why cleanliness and sag matter, and how to decide.
- Conductor screen vs insulation screen in HV cables What the conductor screen and the insulation screen of an HV cable do, how they differ, bonded or strippable, and which Borlink™ grades are made for each.
- Why superclean insulation matters at 220 kV and above Contamination is the enemy of HV insulation life. What “superclean” XLPE means at 220 kV and above, and how sealed, dry and clean storage protects it.
- Borlink™ vs Teflon™: power vs signal cable materials Borlink™ XLPE for high-voltage power cables vs Teflon™ FFR 770 foam for high-frequency signal cables: why each cable type needs a different material.