Materials we supply

Semiconductive screen compound

The carbon-black ‘semicon’ layers on either side of the insulation smooth the electric field so it enters and leaves the dielectric evenly. We supply Borlink™ screen compounds for the same voltage classes as the XLPE grades we supply.

A high-voltage cable has two semiconductive (semicon) layers around the XLPE insulation: the conductor screen over the conductor, and the insulation screen over the outside of the insulation. Both are carbon-filled compounds whose job is to even out the electric field at an interface. For more, see conductor screen vs insulation screen.

Conductor screen vs insulation screen

  • Conductor screen — extruded over the conductor and bonded to the insulation; gives the dielectric a smooth, equipotential surface to sit on.
  • Insulation screen — over the outside of the insulation, either bonded (fully adhered) or strippable (peeled off for jointing). LE0592S and LE0500 are designed for the conductor screen and a bonded insulation screen, and LE0550DC for the conductor and insulation screen of HVDC cables; LE0592S can also be used as the conductor screen in strippable cable constructions. See bonded and strippable screens in our glossary.

Grades we supply

Authorized distribution of Borealis Borlink™ semiconductive compounds, in original sealed packaging (choosing between the AC grades? Compare LE0592S vs LE0500):

GradeVoltage classUse
LE0592SHV AC · up to 230 kVConductor & bonded insulation screen
LE0500EHV AC · above 230 kVSupersmooth semiconductive screen
LE0550DCHVDCSupersmooth screen for XLPE HVDC cables

Typical data compared

Typical values from the current Borlink™ data sheets. They are not specifications; the full tables are on each grade's page.

PropertyLE0592SLE0500LE0550DC
Density1135 kg/m³1120 kg/m³1075 kg/m³
DC volume resistivity (23 °C)< 100 Ω·cm< 100 Ω·cm< 100 Ω·cm
DC volume resistivity (90 °C)< 1000 Ω·cm< 1000 Ω·cm< 1000 Ω·cm
Melt temperature120 – 135 °C120 – 135 °C120 – 130 °C
Pre-drying60 °C / 4 h, dehumidified air60 °C / 4 h, dehumidified air60 °C / 4 h, dehumidified air
Shelf life18 months18 months18 months
Storage temp.10 – 30 °C10 – 30 °C10 – 30 °C

The resistivity figures are the same for all three grades: the choice comes from the voltage class and the cable construction, not from these numbers. For what each layer does, see conductor screen vs insulation screen.

Compatibility matters

Screens are not interchangeable — the screen and the insulation must be a qualified pair, matched for cure system, processing temperature and adhesion (strippable vs bonded), so the three layers co-extrude cleanly in one pass (triple extrusion). We supply screens for the same voltage classes as the Borlink™ insulation grades we supply. The data sheets do not recommend a particular screen–insulation combination; the cable maker selects and qualifies the pair.

Why buy through a stocking distributor

  • Ex-stock Shanghai — core grades held locally for short lead times.
  • Original sealed packaging, dry/clean storage, FIFO rotation — see shelf life, storage and drying by grade.
  • Batch traceability and COA on request; export documentation worldwide.

Tell us your voltage class, cable construction and volume — request a quote → and we reply with availability and data sheets.